中国(上海)自由贸易试验区临港新片区老芦公路536号
021-57525860·13162862074
Home/Product Catalog/Testing Machines
04 / 16 · Product line

Testing MachinesTesting Machines

Mechanical property testing: tensile, compression, bending, impact, fatigue and tribology for metals, composites and polymers. The line contains 29 models; use the filters, comparison tool and quick selector to identify

29models
0Type
GBISO · ASTM
48hResponse time
29 models
Total 29 models · Product Line⚡ Quick Selection Wizard⌕ Product Selector¥ Quotation & Selection Proposal▤ Selection Guide↓ Selection Proposal
RQMMS-2000 Friction & WearTesting Machine
RQMMS-2000Friction & WearTesting MachineSpecifications
RQMMU-10G High TemperatureFriction & WearTesting Machine
RQMMU-10GHigh TemperatureFriction & WearTesting MachineSpecifications
RQMMW-1A Friction & WearTesting Machine
RQMMW-1AFriction & WearTesting MachineSpecifications
RQMWF-003 Testing Machine
RQMWF-003Testing MachineSpecifications
RQMRH-3G HeightFriction & WearTesting Machine
RQMRH-3GHeightFriction & WearTesting MachineSpecifications
RQMRS-10W Testing Machine
RQMRS-10WTesting MachineSpecifications
RQWAW-300C Universal Testing Machine
RQWAW-300CUniversal Testing MachineSpecifications
RQWAW-300G Universal Testing Machine
RQWAW-300GUniversal Testing MachineSpecifications
RQWAW-100 Universal Testing Machine
RQWAW-100Universal Testing MachineSpecifications
RQWEW-300C Universal Testing Machine
RQWEW-300CUniversal Testing MachineSpecifications
RQWEW-300G Universal Testing Machine
RQWEW-300GUniversal Testing MachineSpecifications
RQWEW-100BG High-PrecisionUniversal Testing Machine
RQWEW-100BGHigh-PrecisionUniversal Testing MachineSpecifications
RQWEW-600D Universal Testing Machine
RQWEW-600DUniversal Testing MachineSpecifications
RQWES-300C Universal Testing Machine
RQWES-300CUniversal Testing MachineSpecifications
RQWES-100BG High-PrecisionUniversal Testing Machine
RQWES-100BGHigh-PrecisionUniversal Testing MachineSpecifications
RQWES-600D Universal Testing Machine
RQWES-600DUniversal Testing MachineSpecifications
RQWEW-100B Universal Testing Machine
RQWEW-100BUniversal Testing MachineSpecifications
RQWES-100B Universal Testing Machine
RQWES-100BUniversal Testing MachineSpecifications
RQWDS-10GL classHigh-PrecisionElectronicsUniversal Testing Machine
RQWDS-10GLclassHigh-PrecisionElectronicsUniversal Testing MachineSpecifications
RQWDW-1G classHigh-PrecisionElectronicsUniversal Testing Machine
RQWDW-1GclassHigh-PrecisionElectronicsUniversal Testing MachineSpecifications
RQWDS-1G classHigh-PrecisionElectronicsUniversal Testing Machine
RQWDS-1GclassHigh-PrecisionElectronicsUniversal Testing MachineSpecifications
RQWDW-01D classHigh-PrecisionElectronicsUniversal Testing Machine
RQWDW-01DclassHigh-PrecisionElectronicsUniversal Testing MachineSpecifications
RQWDS-01GD classHigh-PrecisionElectronicsUniversal Testing Machine
RQWDS-01GDclassHigh-PrecisionElectronicsUniversal Testing MachineSpecifications
RQWDW-10L ElectronicsUniversal Testing Machine
RQWDW-10LElectronicsUniversal Testing MachineSpecifications
RQWDS-10L ElectronicsUniversal Testing Machine
RQWDS-10LElectronicsUniversal Testing MachineSpecifications
RQWDW-01D ElectronicsUniversal Testing Machine
RQWDW-01DElectronicsUniversal Testing MachineSpecifications
RQWDS-01D ElectronicsUniversal Testing Machine
RQWDS-01DElectronicsUniversal Testing MachineSpecifications
RQWDS-10 ElectronicsUniversal Testing Machine
RQWDS-10ElectronicsUniversal Testing MachineSpecifications
RQWDW-10 ElectronicsUniversal Testing Machine
RQWDW-10ElectronicsUniversal Testing MachineSpecifications
No matching model. Try another keyword or contact our engineers.

Technical Dossier

Six technical documents from principle to acceptance

Industry Cases

Typical inspection tasks and how this product line solves them.

01
Operating ConditionAutomotive
Challenge
Solution100kN Universal Testing Machine,GB 14166
ResultDocumented test report; repeatability and indication error verified against the standard
02
Operating Condition
ChallengeHRB400
Solution600kN,// Length,GB/T 228.1
ResultDocumented test report; repeatability and indication error verified against the standard
03
Operating Condition
Challenge
Solution,
ResultDocumented test report; repeatability and indication error verified against the standard
FAQ
How do I choose the right configuration?
Send us the specimen material, dimensions and applicable standard; an engineer will propose the model and fixturing, and provide a written selection proposal.
Are the published specifications final?
They are reference values for the standard configuration. Final configuration, price and lead time are stated in the formal quotation.
Do you support sample testing?
Yes. Send samples for measurement; we provide a test report together with the recommended configuration.

Principle

How the measurement works — from physical effect to result.

IndenterObjectiveSpecimenLight SourceData Processing
Principle Notes
  1. (Electronics) () SpecimenLoad,,Software ReH/ReL, Rm, Length A, Z, -/-
FAQ
How do I choose the right configuration?
Send us the specimen material, dimensions and applicable standard; an engineer will propose the model and fixturing, and provide a written selection proposal.
Are the published specifications final?
They are reference values for the standard configuration. Final configuration, price and lead time are stated in the formal quotation.
Do you support sample testing?
Yes. Send samples for measurement; we provide a test report together with the recommended configuration.

Process

Standard operating sequence, with the step where errors most often occur highlighted.

01MeasurementSpecimen →
02(//) →
03→Critical Control Point
04Automatic Loading →Critical Control Point
05Result →
06Report

Typical Duration — Typical cycle: 3–15 min per specimen; the highlighted steps are the main sources of measurement error.

FAQ
How do I choose the right configuration?
Send us the specimen material, dimensions and applicable standard; an engineer will propose the model and fixturing, and provide a written selection proposal.
Are the published specifications final?
They are reference values for the standard configuration. Final configuration, price and lead time are stated in the formal quotation.
Do you support sample testing?
Yes. Send samples for measurement; we provide a test report together with the recommended configuration.

Standards

National and international standards governing the method, calibration and acceptance.

StandardScope
GB/T 228.1Metallic Materials Room Temperature
GB/T 229Metallic Materials
GB/T 7314Metallic Materials Room Temperature
GB/T 16825.1Testing Machine Calibration
ISO 6892-1· ASTM E8/E8M
FAQ
Which standards apply?
Send us the specimen material, dimensions and applicable standard; an engineer will propose the model and fixturing, and provide a written selection proposal.
Are the published specifications final?
They are reference values for the standard configuration. Final configuration, price and lead time are stated in the formal quotation.
Do you support sample testing?
Yes. Send samples for measurement; we provide a test report together with the recommended configuration.

Selection Guide

Match operating conditions to the recommended series, then confirm configuration with an engineer.

Operating ConditionRecommended SeriesWhy
Max Test Force 10kN/20kN/50kN/100kN/300kN/600kNSpecifications are for reference only. Final configuration, price and lead time are stated in the formal quotation.
,Specifications are for reference only. Final configuration, price and lead time are stated in the formal quotation.
PlasticsRubber, Thin Film, Electronics(HeightResolution)Specifications are for reference only. Final configuration, price and lead time are stated in the formal quotation.
OptionalHigh Temperature,,.Specifications are for reference only. Final configuration, price and lead time are stated in the formal quotation.
FAQ
How do I choose the right configuration?
Send us the specimen material, dimensions and applicable standard; an engineer will propose the model and fixturing, and provide a written selection proposal.
Are the published specifications final?
They are reference values for the standard configuration. Final configuration, price and lead time are stated in the formal quotation.
Do you support sample testing?
Yes. Send samples for measurement; we provide a test report together with the recommended configuration.

Test Methods

Sample preparation, measurement, verification and acceptance criteria.

Standard Operating Procedure
  1. GB/T 16825.1 classVerification,0.5 classIndication Error ≤±0.5%, 1 class ≤±1.0%
  2. JJG 762 Verification
Acceptance Criteria

Verify with certified reference blocks: at least 5 evenly distributed points; indication error and repeatability must meet the applicable verification regulation.

Precautions

Run a pre-shift check with a reference block, keep the indenter and specimen surface clean, and recalibrate the measuring system periodically.

FAQ
How do I choose the right configuration?
Send us the specimen material, dimensions and applicable standard; an engineer will propose the model and fixturing, and provide a written selection proposal.
Are the published specifications final?
They are reference values for the standard configuration. Final configuration, price and lead time are stated in the formal quotation.
Do you support sample testing?
Yes. Send samples for measurement; we provide a test report together with the recommended configuration.
Hotline